Testing Protocol
A standardized analytical testing method establishes laboratory procedures for quantifying solvent extractable wax content in paper and board substrates. Paper testing laboratories run TAPPI T 574 to measure petroleum wax levels present in packaging materials intended for moisture barrier applications. Gravimetric evaluation provides quantitative verification of wax application levels across converted stock.
Extraction Process
Organic solvent boiling inside a Soxhlet extraction apparatus dissolves petroleum wax compounds out of shredded paper matrix samples. Procedures outlined in TAPPI T 574 specify solvent selection and reflux cycle counts necessary to ensure complete wax extraction. Solvent choice isolates hydrocarbon waxes while leaving paper fiber matrices and inorganic filler complexes intact.
Controlled heating prevents thermal degradation of extracted organic compounds during distillation recovery.
Content Calculation
Evaporation of the extraction solvent leaves a purified wax residue in a pre-weighed laboratory vessel. Precision mass balances calculate extracted wax percentage relative to oven-dry sample weight according to TAPPI T 574 standards. Accurate wax quantification verifies functional barrier performance against liquid water and water vapor transmission on corrugated board stock.
Non-wax additives that dissolve in the extraction solvent introduce measurement errors if chemical interference is not accounted for during testing. Quality control laboratories use these gravimetric values to confirm compliance with protective packaging specifications.