Reconciling Online Optical Thickness Measurement Drift with Laboratory Mechanical Micrometer Standards in Board Sourcing
Online optical board thickness profiles systematically over-report caliper relative to ISO 534 mechanical lab standards due to surface roughness and compression factors.