Non-Contact Acoustic Inspection Limits on High-Speed Porous Paperboard Barrier Web Converting Operations
Air-coupled acoustic inspection reliably detects delamination and blisters above two millimeters, but fiber scatter masks pinholes below 500 micrometers.