Sizing Metric
Standard quality control protocols in papermaking rely on aqueous dye penetration timing to evaluate internal sizing efficiency. The Hercules size test measures the time required for a standardized acid dye solution to penetrate through a paper sheet and reduce surface reflectance to a predetermined percentage. Papermakers utilize this test method to evaluate hydrophobic sizing chemical performance, such as alkyl ketene dimer or alkenyl succinic anhydride additions in the wet end.
Resistance to aqueous penetration correlates directly with measured time in seconds, offering a benchmark for liquid holdout. Sheet basis weight, caliper and internal pore structure heavily influence test duration alongside hydrophobic additive concentration.
Test Mechanism
Photometric sensors located beneath the paper sample detect reflected light changes as dye solution absorbs into the sheet face. Conducting the Hercules size test involves pouring the specified dye solution into a specimen ring clamped over the top surface of the sample. When liquid migrates through the sheet thickness, surface reflectance drops until reaching a designated cutoff value, typically eighty or sixty percent of initial reflectance.
Board Specification