Migration Testing
Standardised food contact analytical testing measures chemical substance migration from packaging materials into approved testing liquids or polymer adsorbents. Conducted under regulated time and temperature parameters, standard simulant exposure replaces actual food matrices with ethanol solutions, acetic acid or polyoxymethylene to quantify potential chemical transfer. Test results determine regulatory compliance for paperboard cartons intended for direct contact with fatty, aqueous or dry foods.
Migration limits restrict chemical transfer to protect consumer safety.
Extraction Conditions
Laboratory technicians submerge package samples in prescribed simulant liquids within sealed migration cells. During testing, standard simulant exposure subjects packaging materials to accelerated thermal conditions, such as ten days at forty degrees Celsius, to model extended shelf life storage. Test liquids undergo gas chromatography or mass spectrometry analysis to identify photoinitiators, plasticizers and residual monomers.
Substituting olive oil or modified polyphenylene oxide simulates long-term contact with fatty food products. Higher testing temperatures simulate hot-fill packaging conditions.
Limit Evaluation
Gas chromatography measures extracted chemical concentrations against specific migration limits established by food safety authorities. When standard simulant exposure yields values exceeding statutory thresholds, packaging board lots fail compliance certification. Material reformulations require altered barrier coatings or low-migration printing inks.
Test documentation serves as legal proof of regulatory compliance.