Droplet Expulsion
The unmetered ejection of fluid droplets from the metering zone of a printing unit causes unwanted aerosol accumulation and surface contamination across the travelling web. Occurring predominantly in high-speed flexographic presses running low-viscosity UV-curable or energy-curable chemistries, ink spitting deposits fine spatter across machine frames, anilox rolls and printed packaging substrates. Viscoelastic properties in curable resin formulations generate normal forces behind the reverse-angle doctor blade, lifting the edge and releasing pressurized fluid bursts.
The resulting defect manifests as pepper-like spots on solid print areas, background tinting on unprinted corrugated liners and contamination on plate cylinders.
Rheological Mechanism
Fluid accumulation behind the metering tip drives the physical ejection process. As the rotating anilox roll exits the doctoring nip, ink filaments undergo rapid extensional stretching between the cell edges and the underside of the blade. Because UV-curable inks possess high elastic recovery rather than pure Newtonian shear thinning, these stretching fluid filaments resist clean detachment.
Elastic stresses build until the liquid meniscus ruptures, projecting microscopic ink droplets outward onto passing paper webs. The frequency of filament rupture escalates at linear press speeds exceeding three hundred metres per minute, producing continuous ink mist.
Suppression Limits
Blade geometry and fluid rheology determine the mechanical boundary of mist suppression. Thicker, stepped doctor blades possessing higher section moduli resist elastic displacement, suppressing edge flutter that aggravates droplet release. Adjusting ink formulations with monofunctional monomers or specific flow additives reduces the elastic normal stress, yet excessive viscosity dilution degrades cured barrier properties and visual colour density.
Doctor blade contact angles positioned steeper than thirty degrees often decrease spitting frequency, but this steeper angle accelerates blade wear against the ceramic anilox roll.